Application:
For general applications in drive technology, hydraulics, mechanical engineering, plant engineering and tank construction.
Materials:
Body and wetted parts: 1.4571
Temperature range:
-40 to +85 °C (at the connector)
Measurement range:
-30 to +150 °C
Protection class:
IP 69 / IP 69K (with angled plug: IP 65)
Connection:
G 1/4" (with 6 mm protective tube) or G 1/2" (with 6 mm protective tube)
Operating pressure at the thermowell:
max. 270 bar
Measuring element:
1 x Pt100, class A in accordance with DIN EN IEC 60751
Measuring spread (preset)
0°C to +150°C (range and spread (20 K to 300 K) can be changed with free WIKA configuration software in conjunction with the WIKA programming module PU-548 and adapter plug)
Power supply:
10 to 30 V (DC)
Electrical connection:
M 12 plug (A-coded, 4-pole) or angled plug DIN 43650 / EN 175301-803 A (size 3, 4-pole)
Output signal:
4 - 20 mA
Measurement deviation of the measurement transducer (IEC 62828):
± 0.25 K or ± 0,25 % of the range
Note:
WIKA type TR33 (with M 12-plug) or type TR36 (with angled plug)