SPBA-P2R-G18-2P-M12-0,2& (8000210) pressure switch

OT-FESTO036142

Exemplary representation: SPBA-P2R-G18-2P-M12-0,25X
202,32€ incl. VAT
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Material information RoHs compliant
Measured parameter Relative pressure
Measurement process Metal thin film pressure sensor
Operating pressure [bar] -1 to 10
Operating medium Compressed air to ISO 8573-1:2010 [7:4:4]
Information about operating and control medium Oiled operation possible
Control output 2xPNP
Switch function Threshold value with fixed hysteresis
Switching element function Anti-valent
Switch on point [bar] 0,25
Maximum switch on point [bar] 0,4
Switch off point minimum [bar] 0,05
Max. output current DC [mA] 500
Short circuit resistance yes
Operating voltage range DC [V] 21.6 to 26.4
Reverse polarity protection for all electrical connections
Electrical connection M12x1,
4 pin,
acc. to EN 60947-5-2,
Round shape,
Plug
Fastening type Screwable
Pneumatic connection G1/8
Housing material High-alloyed stainless steels
Electrical connection: material PBT
Setting options Fixed setting
Protection category IP65
Corrosion resistant class KBK 4 - particularly severe corrosion stress
CE certificate (see declaration of conformity) to EU EMC directive,
to EU machinery directive
OT-FESTO036142
{{ $t('shop.all.gewicht') }} 50 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 85365019
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}
{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.