CECC-LK (574418) controller

OT-FESTO038616

Exemplary representation: CECC-LK
700,30€ incl. VAT
pcs
{{ $t('shop.display.artikel.hinweis_alternative') }}
{{ $t('shop.display.artikel.eigenschaften_headline') }}
Corrosion resistant class KBK 0 - No corrosion stressing
Permission RCM mark,
c UL us - Listed (OL)
Material information RoHs compliant
Nominal operating voltage DC [V] 24
Operating voltage 19,2 - 30 V DC
Power input 100 mA nominal bei 24 V DC
Max. power supply [A] 6,0
ambient temperature [°C] 0 to 55
Bearing temperature [°C] -25 to 70
Relative humidity 95 %,
Not condensing
Protection category IP20
Protection class III
Product weight [g] 200
Insensitivity test to vibrations according to EN 61131-2
Insensitivity test to shock according to EN 61131-2
Electrical connection technology I/O Bushing strip, pitch 3.5 mm
Status displays LED
CPU data Processor 400 MHz
Digital inputs, quantity 12
Digital inputs, switching logic Positive logic (PNP)
Digital inputs, quick number inputs 2, However max. 180 kHz
Digital inputs, input signal delay 3 ms type
Digital inputs, input voltage / current 24 V DC
Digital inputs, nominal value for TRUE >= 15 VDC
Digital inputs, nominal value for FALSE <= 5 VDC
Digital inputs, potential separation Yes, opto coupler
Digital inputs, status display LED
Max. line length 30 m Eingänge
Digital outputs, quantity 8
Digital outputs, switching logic Positive logic (PNP)
Digital outputs, contact Transistor
Digital outputs, output voltage 24 V DC
Digital outputs, output current 500 mA
Digital outputs, potential separation Yes, opto coupler
Digital outputs, switching frequency max. 1 kHz
Digital outputs, short circuit proof yes
Digital outputs, status display LED
Report CANopen,
I-port,
IO-Link,
Modbus TCP
Fieldbus interface CAN bus
Fieldbus interface, connection technology Sub-D,
9 pin,
Plug
Fieldbus interface, transfer rate 125, 250, 500, 800, 1000kbit/s,
can be set via software
Fieldbus interface, galvanically separated yes
USB interface USB 1.1
Ethernet, connection plug RJ45
Ethernet, number 1
Ethernet, data transfer speed 10/100 Mbit/s
Ethernet supported protocols TCP/IP, EasyIP, Modbus TCP
Programming software CODESYS provided by Festo V3
Programming language Instruction list (AWL),
Contact diagram (KOP),
acc. to IEC 61131-3,
Sequence language,
Function plan,
Structured text
CE certificate (see declaration of conformity) to EU EMC directive
Certified awarding point UL E239998-D1001
IO-Link, report Device V 1.0,
Master V 1.1
IO-Link, communication mode configurable using software,
Device COM1 (4.8 kBaud), COM2 (38.4 kBaud), COM3 (230.4 kBaud),
Master SIO, COM1 (4.8 kBaud), COM2 (38.4 kBaud), COM3 (230.4 kBaud)
IO-Link, port type Device A,
Master B
IO-Link, number of ports Device 1,
Master 4
IO-Link, process data width OUT Master parameterisable, 2-32 Byte
IO-Link, process data width IN Master parameterisable, 2-32 Byte
IO-Link, minimum cycle time Device 3,2 ms,
Master 5 ms
IO link, storage 2 kByte / port
IO-Link Master, output current 3.5 A / port
IO-Link, connection technology Cage Clamp,
Plug,
Device 3 pin,
Master 5-pin
IO-Link, communication C/Q LED green,
C/Q LED red
IO-Link, operation-readiness display L+ LED green on,
L+ LED green off
OT-FESTO038616
{{ $t('shop.all.gewicht') }} 200 g / pcs
{{ $t('shop.display.artikel.zollwarennummer') }} 85371091
{{ $t('shop.all.hersteller') }} Festo
{{ $t('shop.all.dokumente') }}

 
{{ $t('shop.all.unverbindliche_richtwerte') }}
{{ $t('shop.all.spaetbestellservice') }}
{{ countdownAsString }} {{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.spaetbestellservice.hinweis') }}

{{ $t('shop.all.wochenendversand') }}
{{ $t('shop.modules.navi.fruehbucher-spaetbestellhinweis.noch') }} {{ countdownAsString }}

{{ $t('shop.all.wochenendversand.hinweis') }}

An error has occurred!

An error has occurred, please reload this page and try again.