{{ $t('shop.all.spaetbestellservice.hinweis') }}
Diagnose function | Display via LED |
installation position | arbitrary |
Voltage supply requirement | Funktionskleinspannung mit sicherer Trennung (PELV) |
Nominal operating voltage DC [V] | 24 |
Power blackout bridging [ms] | 10 |
residual ripple | 4 Vss |
Power input in nominal operating voltage | 40 - 50 mA |
Permitted voltage oscillations | ± 25 % |
Permission | RCM mark |
CE certificate (see declaration of conformity) | to EU EMC directive |
Continuous impact strength DIN&EC 68 parts 2-82 | Tested to severity class 2 |
Corrosion resistant class KBK | 1 - low corrosion stress |
Bearing temperature [°C] | -20 to 70 |
Relative humidity |
95 %, Not condensing |
Protection category |
IP67, Push in connector in plugged-in condition |
Oscillation strength to DIN/IEC 68 part 2-6 | Tested to severity class 2 |
ambient temperature [°C] | 0 to 55 |
Product weight [g] | 128 |
Electrical connection: measuring system |
M12, 5 pin, socket / container / …. |
Electrical connection: control interface |
M9, 5 pin, Plug |
Control interface |
Digital, CAN bus with Festo protocol, Without closing resistance |
Fastening type | With throughway bores |
Housing material | PBT reinforced |
{{ $t('shop.all.gewicht') }} | 128 g / pcs |
{{ $t('shop.display.artikel.zollwarennummer') }} | 85389091 |
{{ $t('shop.all.hersteller') }} | Festo |